Printing can be performed from the client or from the server.
From the client
It is linked to surgery. If we need to follow up on SequenceCheck, we will do the following:
Operation.ProductID.Index = 0 Operation.ProductID.LabelPrint.PrintCommand = / usr / local / plc / bin / label_print # The label is printed out immediately when the product is finished Operation.ProductID.LabelPrint.Trigger = Operation Operation.ProductID.LabelPrint.PrintEvenABCUsed = Yes Operation.ProductID.LabelPrint.UserDefined.Text.Content = Ok Operation.ProductID.AsociatedPartIndex = 3 # Operation.ProductID.AsociatedPartIndex = 1 # When the product is sent to rework (PLCSENDREW), the label of the defined operation index bellow (0) will be printed out. # The settings of Operation.ProductID.LabelPrint.UserDefined.Text.Content will be temporary blank. WorkPlace.SendToRework.PrintOperationLabel = 0
It is also possible to use a script device.
We will add a device in the client as follows:
#include "drivers / FULL_BROADCAST.drv" workplace.device.labelprint = yes workplace.device.labelprint.driver = FULL_BROADCAST workplace.device.labelprint.settings.type = script workplace.device.labelprint.settings.debug_mode = no
Events for this device will be handled by the appropriate scripts in the / usr / local / plc / bin / device_scripts / labelprint directory.
In the operation, we will replace the "PrintCommand" parameter with
Operation.ProductID.LabelPrint.PrintDevice = labelprint
The print event is "print", as will the script (or script link). For reprint (PLCPRINTLLABEL), the event is "reprint". For the treatment "PLCLABELREPRINT" it is necessary to create a script "plc_label_reprint" in the bin directory. It does not go through the device, as the only parameter it gets the value of the next scan.
Trigger can be set to:
- Product - printed when the cockpit is completed
- Operation - printed during the performed operation (in this case at the cockpit start)
- Start - ???