Generally, this type of an operation checks if the scanned barcode mathes the product ID. It can be called a unique part check. The scanned bar code (or its substring) needs to match the product ID (or its substring).

Mandatory parameters

  • Operation.name.Type = CableCheck
  • Operation.name.Index = (int) index

Other parameters

Bar code settings

  • Operation.name.SelectPattern[i] = Regexp
  • Operation.name.PartStart[i] = int
This parameter in case of an operation type CableCheck defines the start position in the product ID.
  • Operation.name.PartLength[i] = int
  • Operation.name.CheckSumType[i] = int
Possible values of CheckSumType:
0 - No check (default settings)
1 - SumEven + 3*SumOdd MOD 10
2 - SumEven + 3*SumOdd MOD 36
3 - Sum MOD 43 (Code39)
  • Operation.name.SNStore = No | Yes
This parameter is used here to define if the part bar code is different by its prefix or suffix:
No  - Part number consists of Product ID + Suffix
Yes - Part number consists of Prefix + Product ID