Rework procedure
From PlcWiki
(Created page with 'Generally a rework procedure can be done either on a dedicated Rework station or directly on an assembly line. The product is marked as reworked using a control barcode "Sen…')
Newer edit →
Revision as of 16:06, 12 March 2012
Generally a rework procedure can be done either on a dedicated Rework station or directly on an assembly line.
The product is marked as reworked using a control barcode "Send to rework (PLCSENDREW)". It is possible to remove the rework attribute using a barcode "Remove rework (PLCRMREW)".
There are several parameters in a client configuration file which define the behavior to the reworked products:
Second loop of reworked products
When during its assembly the cockpit is found to be reworked, it is marked using a barcode "Send to rework (PLCSENDREW)". Such a product is not deleted from the kernel data when it passes the final station and the product will go the second loop on an assembly line. It is not shown in the product sequence on the client screen, but when it is scanned on any workstation, it is automatically recognized as reworked. The following settings is needed to suppress the error message "Sequence error". Client version 1203091815 or higher is needed.
WorkPlace.ReworkedProductOutOfSequence = No | Yes