Tightening machines control

From PlcWiki

(Difference between revisions)
Jump to: navigation, search
m
Line 38: Line 38:
PLCDREVTM<Channel Number> - Disable REVerse run. The common value of <Channel Number> is 1. So for example PLCDREVTM1
PLCDREVTM<Channel Number> - Disable REVerse run. The common value of <Channel Number> is 1. So for example PLCDREVTM1
 +
 +
 +
== Strict check of tightening program ==
 +
 +
A standard client behavior when the tightening data are being received is that the client searches all tightening operations for the one with a same tightening program as it is in the received tightening result. If no group with the same program is found, the current active group is not changed and the tightening result is assigned to it.
 +
It is possible to activate a feature called '''Strict check of tightening program''', when the tightening program of the received data is compared with a program defined for the current active group. If it is a different one, the tightening data are not accepted (they are not assigned to any tightening group) and the tightening machine is blocked.
 +
To activate that strict logic on the station it is needed:
 +
# Update CLEVER Workstation Client (plc_client) to a version 10.47.71 1112130354 or higher
 +
# Set the configuration parameter
 +
WorkPlace.Tightening.StrictPSetCheck = Yes

Revision as of 13:17, 14 December 2011

Contents

NOK tightening handling

NOK tightening can be handled by PLC Client by the following ways:

  • No special action
  • Activate reverse run (see Reverse run control bellow)
  • Responsible confirmation
  • Stop the conveyor


Reverse run control

It is possible to set tightening operations to control their reverse run. The following parameter is used for this feature:

operation.name.ActivateReverseRunAfterNOK = No | Yes

The loosening job (or Pset or cycle) needs to be defined in tightening machine. If the above parameter is set to "Yes", then this job is automatically selected after NOK tightening. The original job is returned back after the loosening result is received.

If the tightening job is set like that the switch to the reverse run is not enabled, this feature allows loosening only after NOK tightening. If the screw was OK tightened, the operator shouldn't be able to unscrew it.

The default reverse run job number is 99 for machines Atlas Copco and 0 for Georges Renault. In this case it is necessary to specify it in the configuration file by a following parameter (for example):

workplace.devicehub.tmachine_io_combo_1.high_level.device.tmachine_1.settings.looseningjobnumber = 7

If the loosening follows after OK result, the count of reached OK-done screws is decreased by 1. If the previous tightening was NOK or if the count of reached screws is zero, then the count is not decreased.

It is possible to use following bar codes to switch the reverse run on and off. A responsible person (for example the shift leader) can use these barcodes to have the control of an assebly process.

PLCEREVTM<Channel Number> - Enable REVerse run. The common value of <Channel Number> is 1. So for example PLCEREVTM1
PLCDREVTM<Channel Number> - Disable REVerse run. The common value of <Channel Number> is 1. So for example PLCDREVTM1


Barcodes for the tightening machines control

PLCUBTM - UnBlock Tightening Machine

PLCDBTM - Disable Blocking of Tightening Machine

PLCEBTM - Enable Blocking of Tightening Machine

PLCTMJOB<JobNumber> - Selects a tightening job or Pset (or cycle)

PLCEREVTM<Channel Number> - Enable REVerse run. The common value of <Channel Number> is 1. So for example PLCEREVTM1

PLCDREVTM<Channel Number> - Disable REVerse run. The common value of <Channel Number> is 1. So for example PLCDREVTM1


Strict check of tightening program

A standard client behavior when the tightening data are being received is that the client searches all tightening operations for the one with a same tightening program as it is in the received tightening result. If no group with the same program is found, the current active group is not changed and the tightening result is assigned to it. It is possible to activate a feature called Strict check of tightening program, when the tightening program of the received data is compared with a program defined for the current active group. If it is a different one, the tightening data are not accepted (they are not assigned to any tightening group) and the tightening machine is blocked. To activate that strict logic on the station it is needed:

  1. Update CLEVER Workstation Client (plc_client) to a version 10.47.71 1112130354 or higher
  2. Set the configuration parameter
WorkPlace.Tightening.StrictPSetCheck = Yes
Personal tools