Operation definition
From PlcWiki
(Difference between revisions)
Petr.zalabak (Talk | contribs) m (→Operation parameters) |
Petr.zalabak (Talk | contribs) m (→Operation parameters) |
||
Line 34: | Line 34: | ||
== Operation parameters == | == Operation parameters == | ||
- | + | The conveyor can be stopped in case of NOK result of the operation | |
(bool) Operation.''name''.'''SendConveyorStopWhenNOk''' | (bool) Operation.''name''.'''SendConveyorStopWhenNOk''' | ||
- | |||
+ | The product can be sent automatically to a rework procedure using this parameter: | ||
(bool) Operation.''name''.'''SendToReworkWhenNOk''' | (bool) Operation.''name''.'''SendToReworkWhenNOk''' | ||
- | + | ||
(bool) Operation.''name''.'''InvalidLabelAllowed''' = '''Yes''' | No | (bool) Operation.''name''.'''InvalidLabelAllowed''' = '''Yes''' | No |
Revision as of 15:04, 15 February 2011
Each operation needs to be defined by its index and type. All other parameters are optional, but some of them are necessary for a valuable operation definition:
Operation.name.Type = <Operation type> Operation.name.Index = <Operation index>
for example: Operation.AirbagSN.Type = Serial Operation.AirbagSN.Index = 2
A parameter name joins all operation parameters together.
Operation type can be one of the following ones:
SequenceCheck ProductConfiguration LastWPCheck Serial PartCheck PartCode CableCheck (Poka-Yoke Check) Tightening VisualCheck OutputCheckCorrection OutputCheck PidWrite ixpioSignal VisionSensor PreSequence Measurement RackPartCheck BlindAudit SerialInput
Operation parameters
The conveyor can be stopped in case of NOK result of the operation
(bool) Operation.name.SendConveyorStopWhenNOk
The product can be sent automatically to a rework procedure using this parameter:
(bool) Operation.name.SendToReworkWhenNOk
(bool) Operation.name.InvalidLabelAllowed = Yes | No For safety critical operations like VW baugruppen it should be set to "No". Then the control bar code "Invalid label" (PLCIL) is not accepted. The logic is, that a product without safety critical documented items is not cempletely assembled and should not be released to the customer. If it is not possible to scan the part label, the part needs to be changed to the correct one. So then it is necessary to assemble another piece or sent the product to a rework station.