There are two workstations (B7 and B6) for the X-beam assembly. These stations are not connected to CLEVER kernel and they work using a barcodes for "Default model" (PLCDMnn). When the specification of the model is scanned, the client searches the information in a file /usr/local/plc/etc/models_B7(6), which looks like:
# PLC - Product Line Control (c) CLEVER System s.r.o. 2001 # Configuration table for default models # When PLCDMnn is scanned, the value nn is searched as ModelNo in the list below. # Then each operation has its basic definition in the following format: # # OpIndex: Plan PartNum BarCode|RackNumber[ LowerLimit UpperLimit] # # RackNumber is used as a value for the V parameter sent to PLC. # LowerLimit and UpperLimit are used for the Measurement evaluation. ModelNo = 01 ModelName = X Y413 LHD ModelPartNum = 31332018 0: 1 1: 0 2: 1 31332018 1 3: 5 4: 1 Turn 180 0 5: 4 6: 1 Measurement 0 10000 30000 7: 1 8: 1 Release 1 ModelNo = 11 ModelName = X Y413 RHD ModelPartNum = 31332019 0: 1 1: 0 2: 1 31332019 11 3: 4 4: 1 Turn 180 0 5: 4 6: 1 Measurement 0 10000 30000 7: 1 8: 1 Release 1
When the product is finished, the next one is automatically started using the same Default Model specification.
When it is needed to change the Default model, the new specification can be scanned. Default Model specification can be scanned only when the product is not yet started.