Enabling merge point functionality
workplace.device.scanner1 = yes workplace.device.scanner1.settings.type = serial workplace.device.scanner1.settings.tty = /dev/ttyS0 workplace.device.scanner1.settings.speed = 9600 workplace.device.scanner1.settings.log_file = /usr/local/plc/log/scanner1.log workplace.device.scanner1.settings.no_delim = yes workplace.device.scanner1.settings.sentence_timeout = 100 workplace.device.scanner1.settings.debug_mode = yes workplace.device.scanner1.settings.Name = "Auto scanner" # Name displayed in the message window, not required workplace.device.scanner1.settings.RescanNOKProductIDs = yes # Rescan product that was not expected when another product scanned by a different scanner is completed workplace.device.scanner1.settings.ConveyorID = 9 # Set conveyor ID to this value when anything is scanned by this scanner #workplace.device.scanner1.settings.Destination = 11 # Set conveyor destination to this value when anything is scanned by this scanner #workplace.device.scanner1.event.scannerinput = "^prefix(.+)suffix\r?\n?$" workplace.device.scanner1.event.scannerinput = "^\x02?(.+?)\x03?\r?\n?$" workplace.device.scanner1.event.scannerinput.input = [[:]]
workplace.device.scanner2 = yes workplace.device.scanner2.settings.type = serial workplace.device.scanner2.settings.tty = /dev/ttyS1 workplace.device.scanner2.settings.speed = 9600 workplace.device.scanner2.settings.log_file = /usr/local/plc/log/scanner2.log workplace.device.scanner2.settings.no_delim = yes workplace.device.scanner2.settings.sentence_timeout = 100 workplace.device.scanner2.settings.debug_mode = yes workplace.device.scanner2.settings.Name = "Manual scanner" workplace.device.scanner2.settings.RescanNOKProductIDs = yes workplace.device.scanner2.settings.ConveyorID = 10 #workplace.device.scanner2.event.scannerinput = "^prefix(.+)suffix\r?\n?$" workplace.device.scanner2.event.scannerinput = "^\x02?(.+?)\x03?\r?\n?$" workplace.device.scanner2.event.scannerinput.input = [[:]]
The count of scanner devices is unlimited
PLCSCO
Barcode PLCSCO (Set COnveyor) allows setting conveyor ID and conveyor destination to desired values. The format is as follows:
PLCSCO<conveyorID>-<destination>
If <destination> is missing, it is set to undefined value.
Example:
PLCSCO4-10
PLCCLSE
Barcode PLCCLSE means Clear Last Sequence Errors - i.e. clear all rescanned NOK product IDs.
Use it to get rid of any automatically rescanned product IDs.