Each operation needs to be defined by its index and type. All other parameters are optional, but some of them are necessary for an valuable operation definition:
Operation.name.Type = <Operation type> Operation.name.Index = <Operation index>
for example: Operation.AirbagSN.Type = Serial Operation.AirbagSN.Index = 2
A parameter name joins all operation parameters together.
Operation type can be one of the following ones:
SequenceCheck ProductConfiguration LastWPCheck Serial PartCheck PartCode CableCheck Tightening VisualCheck OutputCheckCorrection OutputCheck PidWrite ixpioSignal VisionSensor PreSequence Measurement RackPartCheck BlindAudit SerialInput
Operation parameters
(bool)Operation.name.SendConveyorStopWhenNOk
(bool)Operation.name.SendToReworkWhenNOk