SAS Gölcük

From PlcWiki

(Difference between revisions)
Jump to: navigation, search
 
(8 intermediate revisions not shown)
Line 1: Line 1:
-
Stations that use ethernet NICs instead of Wi-Fi have association disabled in '''/etc/wpa_supplicant/wpa_supplicant.conf'''
+
[[Plants]]
-
Uncomment ESSID to reenable.
+
== Important Links ==
-
These are so far:
+
[http://plcgolsql:8080/clea CLEA] |  [http://plcgolsql:8080/SasMenu SAS menu]| [http://plcgolsql:8080/ctt CTT] | [http://plcgolsql:8080/probe Probe]  | [http://plcgolsql/zabbix Zabbix] OFF
-
* 10.70.4.37 DP
+
-
* 10.70.4.38 DS
+
-
The order of main, left and right component is now enforced on DP chain.
+
== Dataflow description ==
-
If any component is missing (i.e. convertorPID, convertorL or  convertorR not working properly), the supply of cars to DP kernel will stop until the missing component is delivered or until the PMC chain is told to skip the component with a special command:
+
[http://plcgol362krnl:8080/pmc.svg 362] | [http://plcgol363krnl:8080/pmc.svg 363] | [http://plcgol460krnl:8080/pmc.svg 460]
-
qdbus --system cz.clever.pmc.multiplexor / cz.clever.pmc.DirQ.resetExpectedOrderNumber
+
Dataflow description
-
== Important Links ==
+
== Project layout ==
-
[http://plcgolsql:8081/clea CLEA] | [http://plcgolsql:8081/ctt CTT] | [http://plcgolsql:8081/probe Probe] | [http://plcgolsql:8081/CleverMenu Clever menu] | [http://plcgolsql/zabbix Zabbix] OFF
+
Stations that use ethernet NICs instead of Wi-Fi have association disabled in '''/etc/wpa_supplicant/wpa_supplicant.conf'''
 +
Uncomment ESSID to reenable.
-
== Dataflow description ==
+
These are so far:
 +
* 10.70.4.37 DP
 +
* 10.70.4.38 DS
-
[http://plcgolsql:8081/pmc.svg PMC] OFF
 
-
Dataflow description
+
The order of main, left and right component is now enforced on DP chain.
 +
If any component is missing (i.e. convertorPID, convertorL or  convertorR not working properly), the supply of cars to DP kernel will stop until the missing component is delivered or until the PMC chain is told to skip the component with a special command:
-
== Project layout ==
+
qdbus --system cz.clever.pmc.multiplexor / cz.clever.pmc.DirQ.resetExpectedOrderNumber

Current revision as of 09:02, 25 February 2020

Plants

Important Links

CLEA | SAS menu| CTT | Probe | Zabbix OFF


Dataflow description

362 | 363 | 460

Dataflow description


Project layout

Stations that use ethernet NICs instead of Wi-Fi have association disabled in /etc/wpa_supplicant/wpa_supplicant.conf

Uncomment ESSID to reenable.

These are so far:

  • 10.70.4.37 DP
  • 10.70.4.38 DS


The order of main, left and right component is now enforced on DP chain.

If any component is missing (i.e. convertorPID, convertorL or convertorR not working properly), the supply of cars to DP kernel will stop until the missing component is delivered or until the PMC chain is told to skip the component with a special command:

qdbus --system cz.clever.pmc.multiplexor / cz.clever.pmc.DirQ.resetExpectedOrderNumber
Personal tools