How to

From PlcWiki

(Difference between revisions)
Jump to: navigation, search
 
(2 intermediate revisions not shown)
Line 5: Line 5:
'''Invalid part'''
'''Invalid part'''
-
PIC: [[File:Screenshot_2018-08-27_15-06-58.png]]
+
[[File:Screenshot_2018-08-27_15-06-58.png]]
When invalid part is scanned red alert appears in log frame …
When invalid part is scanned red alert appears in log frame …
Line 14: Line 14:
'''Unknown barcode'''
'''Unknown barcode'''
-
PIC:
+
Client doesn’t recognize scanned barcode at all. Wasn’t able to assign input to any operation.  
Client doesn’t recognize scanned barcode at all. Wasn’t able to assign input to any operation.  
Line 23: Line 23:
'''Invalid (damaged/missing) barcode'''
'''Invalid (damaged/missing) barcode'''
-
PIC [[File:Screenshot_2018-08-27_15-10-53.png]]
+
[[File:Screenshot_2018-08-27_15-10-53.png]]
 +
 
If a barcode is unreadable but it’s a correct part, a special barcode can be scanned to continue the operation.
If a barcode is unreadable but it’s a correct part, a special barcode can be scanned to continue the operation.
Line 30: Line 31:
'''Unable to convert a barcode'''
'''Unable to convert a barcode'''
-
PIC: unable to convert …
+
unable to convert …
Client recognized input and assigned to operation, but can’t internally translate input to part number.
Client recognized input and assigned to operation, but can’t internally translate input to part number.
Line 39: Line 40:
'''Question marks in operations’ frame'''
'''Question marks in operations’ frame'''
-
PIC [[File:Screenshot_2018-08-27_13-55-15.png]]
+
[[File:Screenshot_2018-08-27_13-55-15.png]]
Operation is requested, but not appropriate part was found in incoming data.  
Operation is requested, but not appropriate part was found in incoming data.  

Current revision as of 07:25, 21 January 2019

Issues

To bypass these issues temporarily one of the emergency barcodes PLCIL or PLCABCNEXT can be used.

Invalid part

File:Screenshot_2018-08-27_15-06-58.png

When invalid part is scanned red alert appears in log frame …

Solution: - Scan correct part. - “Part equivalence” can be used in case that part is equivalent to requested. Barcode PLC temporarily can be used in emergency. Alternatively, Part equivalence module can be used.

Unknown barcode


Client doesn’t recognize scanned barcode at all. Wasn’t able to assign input to any operation.

Solution: Ensure that part being used is correct part. Most probably this barcode is not covered by SelectPattern in operations’ configuration. Has to be fixed in Clea.

Invalid (damaged/missing) barcode

File:Screenshot_2018-08-27_15-10-53.png

If a barcode is unreadable but it’s a correct part, a special barcode can be scanned to continue the operation.

Solution: - Ensure that it is correct part visually, scan emergency barcode PLCIL.

Unable to convert a barcode

unable to convert …

Client recognized input and assigned to operation, but can’t internally translate input to part number.

Solution: - Has to be fixed in Clea in Quality condition configuration.

Question marks in operations’ frame

File:Screenshot_2018-08-27_13-55-15.png

Operation is requested, but not appropriate part was found in incoming data.

Solution: - Has to be fixed in Clea in Quality condition configuration.