Emergency strategy

From PlcWiki

(Difference between revisions)
Jump to: navigation, search
(Created page with '== Three levels of emergency strategy == === 1st level === Data are sent to CLEVER System via an alternative application (ASEC, LES) === 2nd level === A data connection from …')
m
Line 4: Line 4:
=== 1st level ===
=== 1st level ===
Data are sent to CLEVER System via an alternative application (ASEC, LES)
Data are sent to CLEVER System via an alternative application (ASEC, LES)
-
 
=== 2nd level ===
=== 2nd level ===
Line 11: Line 10:
=== 3rd level ===
=== 3rd level ===
A network connection between stations and the kernel is lost. A 2-D specification barcode is scanned on each station, the data are sent to the local Kernel, which temporary replaces the functionality of the main Kernel.
A network connection between stations and the kernel is lost. A 2-D specification barcode is scanned on each station, the data are sent to the local Kernel, which temporary replaces the functionality of the main Kernel.
 +
== Scanning of 2-D specification barcode (Client configuration) ==
== Scanning of 2-D specification barcode (Client configuration) ==
-
 
   
   
  #=======================
  #=======================

Revision as of 15:33, 27 March 2014

Contents

Three levels of emergency strategy

1st level

Data are sent to CLEVER System via an alternative application (ASEC, LES)

2nd level

A data connection from JIS (WSW) and ASEC (LES) is totaly lost, but the connection between stations and the kernel is established. A 2-D specification barcode is scanned on the first station, the data are sent to the Kernel and prepared for all other stations.

3rd level

A network connection between stations and the kernel is lost. A 2-D specification barcode is scanned on each station, the data are sent to the local Kernel, which temporary replaces the functionality of the main Kernel.


Scanning of 2-D specification barcode (Client configuration)

#=======================
#[Product configuration]
#=======================
#
Operation.Configuration.Type = ProductConfiguration
Operation.Configuration.Index = 9
operation.Configuration.SelectPattern[0] = ^@CS
#Workplace.SendProductConfigurationToKernel = No
operation.Configuration.SendDataToKernel = Yes
operation.Configuration.ProductSpecification.FullData = Yes
#operation.Configuration.ProductSpecification.OutgoingFieldSeparator = \xC2\x8D # for JIS data
operation.Configuration.ProductSpecification.OutgoingFieldSeparator = \x0D\x0A # for WSW data
# The parameter ScannedDataStartPosition should be 6 + KennLength
operation.Configuration.ProductSpecification.ScannedDataStartPosition = 14 # Zwickau (VIN example: 13402471)
#operation.Configuration.ProductSpecification.ScannedDataStartPosition = 17 # Golcuk (VIN example: TTGYDD04749)
#operation.Configuration.ProductSpecification.ScannedDataStartPosition = 32