Revision as of 07:33, 14 May 2010
Generally, this type of an operation checks if the scanned part is the correct one, which is requested for this product.
Mandatory parameters
- Operation.name.Type = PartCheck
- Operation.name.Index = (int) index
Other parameters
Bar code settings
- Operation.name.SelectPattern[i] = Regexp
- Operation.name.PartStart[i] = int
- Operation.name.PartLength[i] = int
- Operation.name.CheckSumType = int
Possible values of CheckSumType[i]: 0 - No check (default settings) 1 - SumEven + 3*SumOdd MOD 10 2 - SumEven + 3*SumOdd MOD 36 3 - Sum MOD 43 (Code39)